Easytherm EMP/EMP ID/ETP 112-136
Up to 140°C
Easytherm is the new mould temperature control unit characterized by user- friendliness, flexibility and reliability, for injection and blow moulding and extrusion processes.
A new interior and exterior layout, redesigned ergonomic control, coupled with high-end components, characterise a versatile machine that guarantees reliability and long term performances.
Easytherm operates at temperatures up to 140°C. Maximum reliability is assured thanks to technologies such as magnetic driven pumps or Flow Through Heaters.
The large 4.3” TFT high contrast display is tilted to ensure easy reading. Navigation in the sub menus is managed via a convenient knob.
Easytherm is already set up for use in Industry 4.0 environments with a wide range of communication protocols, including OPC-UA platform and is Winfactory 4.0 ready.
-
Precise temperature control
-
Easy to use
-
Robust construction for industrial applications
-
Up to 140°C operating temperature
Benefits of the Easytherm EMP/EMP ID/ETP ID 112-136 Temperature Controller Features
Easy programming and real-time system visibility.
Configurable performance to match specific moulding requirements.
Built for continuous, reliable operation
Redesigned internal layout with best-in-class components and a compact footprint.
Accurate and stable temperature control up to 140°C.
Overview
- High capacity water temperature control maintains stable temperatures up to 140°C.
- Wide range of flow, pressure and temperature options.
- Simple, intuitive set up and operation with LED status indicators
- Built for long term reliability and reduced downtime.
- Indirect cooling mode for safe, efficient cooling.
Additional Features
- Three electrical feed options: 38/3/60, 400/3/5- and 460/3/60 (V, Ph, Hz)
- The refilling of the process water can be done from the cooling water circuit or from the dedicated line
- Pressurized water process fluid system
- Tubular heaters are realized with Incoloy 800 to guarantee a high corrosive resistance
Available Options
- 2 or 4 ways manifold
- Additional filters
- Anti-corrosive kit (to avoid any risk of galvanic corrosion with the consequent risk of damages and contaminants release)
- Acoustic alarm
- Communication interface (Current Loop and Modbus RTU)
- OPC-UA Communication Interface; for ETP Models only
Resources
Brochures
Specifications
Specification Tables
| Model | EMP 112 | EMP 118 | EMP 124 |
|---|---|---|---|
| Maximum Temperature | 140°C | 140°C | 140°C |
| Heating Power | 12 kW | 18 kW | 24 kW |
| Cooling Power (kW) / ΔT = 110°C |
100 Coil or 125 Plates |
100 Coil or 125 Plates |
100 Coil or 125 Plates |
| Heat Exchanger | Coil or Plate | Coil or Plate | Coil or Plate |
| Maximum Flow Rate Pump - P8 Maximum Flow Rate Pump - P9 Maximum Flow Rate Pump - P12 Maximum Flow Rate Pump - P14 |
40 l/min 60 l/min 100 l/min 200 l/min |
40 l/min 60 l/min 100 l/min 200 l/min |
40 l/min 60 l/min 100 l/min 200 l/min |
| Pump Head - P8 Pump Head - P9 Pump Head - P12 Pump Head - P14 |
60 m 60 m 60 m 37 m |
60 m 60 m 60 m 37 m |
60 m 60 m 60 m 37 m |
| Pump Load Power - P8 Pump Load Power - P9 Pump Load Power - P12 Pump Load Power - P14 |
0.75 kW 0.75 kW 1.5 kW 1.5 kW |
0.75 kW 0.75 kW 1.5 kW 1.5 kW |
0.75 kW 0.75 kW 1.5 kW 1.5 kW |
| Dimensions L x W x H |
1,143 x 598 x 1,560 mm |
1,143 x 598 x 1,560 mm |
1,143 x 598 x 1,560 mm |
| Model | EMP 112 ID | EMP 118 ID | EMP 124 ID |
|---|---|---|---|
| Maximum Temperature | 90°C | 90°C | 90°C |
| Heating Power | 12 kW | 18 kW | 24 kW |
| Cooling Power (kW) / ΔT = 70°C |
120 Direct | 120 Direct | 120 Direct |
| Heat Exchanger | Direct Injection | Direct Injection | Direct Injection |
| Maximum Flow Rate Pump - P8 Maximum Flow Rate Pump - P9 Maximum Flow Rate Pump - P12 Maximum Flow Rate Pump - P14 |
N / A 60 l/min 100 l/min 200 l/min |
N / A 60 l/min 100 l/min 200 l/min |
N / A 60 l/min 100 l/min 200 l/min |
| Pump Head - P8 Pump Head - P9 Pump Head - P12 Pump Head - P14 |
N / A 60 m 60 m 37 m |
N / A 60 m 60 m 37 m |
N / A 60 m 60 m 37 m |
| Pump Load Power - P8 Pump Load Power - P9 Pump Load Power - P12 Pump Load Power - P14 |
N / A 0.75 kW 1.5 kW 1.5 kW |
N / A 0.75 kW 1.5 kW 1.5 kW |
N / A 0.75 kW 1.5 kW 1.5 kW |
| Dimensions L x W x H |
1,143 x 598 x 1,560 mm |
1,143 x 598 x 1,560 mm |
1,143 x 598 x 1,560 mm |
| Model | ETP 112 ID | ETP 118 ID | ETP 124 ID |
|---|---|---|---|
| Maximum Temperature | 90°C | 90°C | 90°C |
| Heating Power | 12 kW | 18 kW | 24 kW |
| Cooling Power (kW) / ΔT = 50°C |
120 Direct | 120 Direct | 120 Direct |
| Heat Exchanger | Direct Injection | Direct Injection | Direct Injection |
| Maximum Flow Rate Pump - P8 Maximum Flow Rate Pump - P9 Maximum Flow Rate Pump - P12 Maximum Flow Rate Pump - P14 |
N / A 60 l/min 100 l/min 200 l/min |
N / A 60 l/min 100 l/min 200 l/min |
N / A 60 l/min 100 l/min 200 l/min |
| Pump Head - P8 Pump Head - P9 Pump Head - P12 Pump Head - P14 |
N / A 60 m 60 m 37 m |
N / A 60 m 60 m 37 m |
N / A 60 m 60 m 37 m |
| Pump Load Power - P8 Pump Load Power - P9 Pump Load Power - P12 Pump Load Power - P14 |
N / A 0.75 kW 1.5 kW 1.5 kW |
N / A 0.75 kW 1.5 kW 1.5 kW |
N / A 0.75 kW 1.5 kW 1.5 kW |
| Dimensions L x W x H |
1,143 x 598 x 1,560 mm |
1,143 x 598 x 1,560 mm |
1,143 x 598 x 1,560 mm |
Specifications may change without notice. Contact Thermal Care for the most current information. Note that graphics and photos are for illustrative purposes only and may not accurately reflect each product or the most current design.